You can get different sizes of pvc and you can run 2 3 lines in one run.
Pvc chase from basement to attic.
Now that you have run wires from your outlet to the basement or the attic you may need to run the wire from the attic to the basement.
Running wires from the attic to the basement.
A conduit usually goes from a wall plate or some other firm destination to another solid destination.
But if it s only on one side o.
4 posts read 3 904 times.
The only straight shot from attic to basement that i can see is the cold air return which has an grate on each floor in roughly the same place.
Then i ran my wiring bundles from the attic down to the 2nd floor.
Pvc from basement to attic i m in the middle of doing some remodeling work on my house and i figure now is as good as a time as any to ask this.
09 19 2016 09 45 am somersetresident.
Ideally your house included a future tube which is a pvc pipe running from the basement to the attic specifically for this purpose.
This pipe utilized a chase which is about 12 x 18 x 16ft high so there s plenty of room to run conduit for future electrical circuits or low voltage runs from the basement to attic if needed down the road.
On the first floor i also cut a hole in the wall to fish the run from the 2nd floor and then ran that to the basement.
Builder can put in an 1 1 2 pvc conduit from basement to attic for 412.
Any pointers will help.
It seems no matter what you will have to open a couple walls but might not be as bad as you think.
I go down to the basement and i see many pvc pipes.
I m wanting to run some future proof low voltage conduit from attic to basement unfinished area where i have a structured media enclosure mounted.
From a wall switch box to a breaker panel while a chase often simply goes from one open space to another.
Could anyone explain the benefits of this conduit.
If you have a rigid line then you can open up one wall on second floor to drill to attic and first and then drill up to first from basement.
I only have the basic idea that it s going to run inside walls and can be used in the future for running wires from basement to each floor.
Does anyone know how to identify the 2 pvc chase from basement to attic which was part of the upgrade package.
I believe that this went into effect in 1992 with ubc 702 8.
Since i need to re insulate the chase exterior wall and button up 2 floors of drywall patch i figured now s the time to do it.
One portion of the basement is unfinished.
As a follow up on my last post what i referred to as a chase is actually called a vertical fire block that has the same function as the horizontal fire block that surrounds the flues of prefabricated chimineys on attic floors.