Roof Tile Counter Flashing Detail

Clay Tile And Concrete Tile Everybody Needs A Roof Concrete Tiles Clay Tiles Clay Roofs

Clay Tile And Concrete Tile Everybody Needs A Roof Concrete Tiles Clay Tiles Clay Roofs

Pin On Roof Tie In

Pin On Roof Tie In

Pin On Roofing Ideas

Pin On Roofing Ideas

Pin On Roofing Waterproof

Pin On Roofing Waterproof

Pin On Roofing

Pin On Roofing

Pin On Graphic Standards

Pin On Graphic Standards

Pin On Graphic Standards

Sp 14 usp sp clad metal joint flashing detail.

Roof tile counter flashing detail.

The extra kick at the bottom of the face directs run off away from the structure. Extend the clay tile flashing under the tile a minimum of 6 inches or as specified by the tile manufacturer. Typically 10 by 8 inch 253 mm x 203 mm flashing is chosen. Sp 19 usp sp removable equipment curb flashing detail.

Sp 16 usp sp gutter flashing detail. This drip edge flashing provides protection from water damage along the eaves and rake of a roof. This collection of 18 articles animations and videos identifies the critical roof flashing areas illustrates durable roof flashing details and shows how to flash roofs right in the real world. Sp 17 usp sp surface mounted counter flashing detail.

3 06 valley termination onto roof plane 11 3 07 flashing and counter flashings at wall abutments 11 3 08 head and apron flashing 12 3 09 standard curb mounted skylights chimneys etc. Further your step flashing pieces need to be 10 inches 254 mm long and at least 2 inches 50 mm wider than the exposure of the shingle you re using. The flashing of the head of a batten seam roof at a wall is shown in this detail. Gibraltar drip edge flashing can be used with asphalt shingles or metal roofing panels.

Copper flashing is locked into this edge and extends at least 8 up the wall. Sp 15 usp sp locking fascia edge flashing detail. Sp 20 usp sp non removable equipment curb flashing. Step flashing consists of short pieces of flashing each installed to overlap the shingle in the course below and to be overlapped by the shingle in the course above.

15 3 11 batten installation 16 3 12 tile installation 17 3 13 flat low medium and high profile tile 19 3 14 valleys. More product details close. Tile roof details recommended at openings and walls at walls dormers chimneys and other vertical surfaces extend the flashing up at least 6 inches and counterflash. For example 3 tab shingles usually have a 5 5 8 inch 143 mm exposure.

Cad details document name pdf dwg download all cad construction details 37 1 mb 3 4 mb mc01 identification of roof areas 694 kb 167 kb mc01a single layer underlayment 678 kb 302 kb mc01b double layer underlayment 711 kb 322 kb mc02 vent pipe flashing 626 kb 349 kb mc03 valley. Sp 18 usp sp cut in reglet counter flashing detail. 14 3 10 pipes turbines vents etc. Step flashing sidewalls on roofs covered with asphalt shingles wood shingles shakes and slate should be flashed using step flashing like you see here.

Pin On Flashing

Pin On Flashing

Pin On Week 6

Pin On Week 6

Pin On Roof

Pin On Roof

Pin On Skylite

Pin On Skylite

Source : pinterest.com